Actron CP7529 Wartungshandbuch Seite 9

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 26
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 8
IMPORTANT
4. Connect RED and BLACK Battery Clips on Negative Ground Electrical
Systems.
· Connect RED to positive (+) battery post.
· Connect BLACK to engine ground.
On 6-volt electrical systems, use an auxiliary 12-volt battery to
power timing light. Connect BLACK clip to negative (-) post and
RED clip to positive (+) post on auxiliary 12- volt battery. Use 18
AWG or larger wire to connect 12-volt battery negative (-) terminal
to a good engine ground.
On 12-volt Positive Ground electrical systems, connect BLACK clip
to negative (-) battery post and RED clip to engine ground. DO NOT
USE the positive battery post.
On engines equipped with a breaker point ignition system, it will be
necessary to set the point dwell before adjusting the timing. Always
follow the manufacturers specifications and test procedures for
adjusting dwell angle and idle speed.