Section 2. Automotive Testing
The digital multimeter is a very useful tool for
trouble-shooting automotive electrical sys-
tems. This section describes how to use the
digital multimeter to test the starting and charg-
ing system, ignition system, fuel system, and
engine sensors. The digital multimeter can
also be used for general testing of fuses,
switches, solenoids, and relays.
General Testing
The digital multimeter can be used to test
fuses, switches, solenoids, and relays.
Testing Fuses
This test checks to see if a fuse is blown. You
can use this test to check the internal 15A
fuse inside the digital multimeter.
If you hear tone - Fuse is good.
If you don’t hear tone - Fuse is blown
and needs to be replaced.
NOTE: Always replace blown fuses with
same type and rating.
Testing Switches
This test checks to see if a switch “Opens” and
“Closes” properly.
Fig. 16
Red Black
Typical "Push"
Button Switch
To test Switches (see Fig. 16):
1. Insert BLACK test lead into COM test
lead jack.
2. Insert RED test lead into
test
lead jack.
3. Turn multimeter rotary switch to
200
function.
4. Touch RED and BLACK test leads to-
gether to test continuity.
Listen for tone to verify proper operation.
5. Connect BLACK test lead to one side of
switch.
6. Connect RED test lead to other side of
switch.
Listen for tone:
If you hear tone - The switch is closed.
If you don’t hear tone - The switch is
open.
7. Operate switch.
Listen for tone:
To test Fuses (see Fig. 15):
1. Insert BLACK test lead into COM test
lead jack.
2. Insert RED test lead into
test
lead jack.
3. Turn multimeter rotary switch to
200
function.
4. Touch RED and BLACK test leads to-
gether to test continuity.
Listen for tone to verify proper operation.
5. Connect RED and BLACK test leads to
opposite ends of fuse.
Listen for tone:
Fig. 15
Red
Black
Fuse
Seitenansicht 12